Bibcode
Moncelsi, Lorenzo; Ade, Peter A. R.; Angilè, Francesco E.; Benton, Steven J.; Devlin, Mark J.; Fissel, Laura M.; Gandilo, Natalie N.; Gundersen, Joshua O.; Matthews, Tristan G.; Netterfield, C. Barth; Novak, Giles; Nutter, David; Pascale, Enzo; Poidevin, F.; Savini, Giorgio; Scott, Douglas; Soler, Juan Diego; Spencer, Locke D.; Truch, Matthew D. P.; Tucker, Gregory S.; Zhang, Jin
Bibliographical reference
Monthly Notices of the Royal Astronomical Society, Volume 437, Issue 3, p.2772-2789
Advertised on:
1
2014
Citations
26
Refereed citations
17
Description
A cryogenic achromatic half-wave plate (HWP) for submillimetre
astronomical polarimetry has been designed, manufactured, tested and
deployed in the Balloon-borne Large-Aperture Submillimeter Telescope for
Polarimetry (BLASTPol). The design is based on the five-slab
Pancharatnam recipe and it works in the wavelength range 200-600 μm,
making it the broadest-band HWP built to date at (sub)millimetre
wavelengths. The frequency behaviour of the HWP has been fully
characterized at room and cryogenic temperatures with incoherent
radiation from a polarizing Fourier transform spectrometer. We develop a
novel empirical model, complementary to the physical and analytical ones
available in the literature, that allows us to recover the HWP Mueller
matrix and phase shift as a function of frequency and extrapolated to 4
K. We show that most of the HWP non-idealities can be modelled by
quantifying one wavelength-dependent parameter, the position of the HWP
equivalent axes, which is then readily implemented in a map-making
algorithm. We derive this parameter for a range of spectral signatures
of input astronomical sources relevant to BLASTPol, and provide a
benchmark example of how our method can yield improved accuracy on
measurements of the polarization angle on the sky at submillimetre
wavelengths.