Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Escalante Del Valle, A.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Taurok, A.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Marchesini, I.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Bilin, B.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Dorney, B.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Kalsi, A. K.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Seva, T.; Starling, E.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Trocino, D.; Tytgat, M.; Verbeke, W.; Vit, M. et al.
Referencia bibliográfica
Journal of Instrumentation, Volume 13, Issue 06, pp. P06015 (2018).
Fecha de publicación:
6
2018
Número de citas
477
Número de citas referidas
255
Descripción
The CMS muon detector system, muon reconstruction software, and
high-level trigger underwent significant changes in 2013–2014 in
preparation for running at higher LHC collision energy and instantaneous
luminosity. The performance of the modified system is studied using
proton-proton collision data at center-of-mass energy √s=13 TeV,
collected at the LHC in 2015 and 2016. The measured performance
parameters, including spatial resolution, efficiency, and timing, are
found to meet all design specifications and are well reproduced by
simulation. Despite the more challenging running conditions, the
modified muon system is found to perform as well as, and in many aspects
better than, previously. We dedicate this paper to the memory of Prof.
Alberto Benvenuti, whose work was fundamental for the CMS muon detector.